Un des principaux développeurs mondiaux de logiciels VMS et PSIM intelligents
Où acheter
Contactez-nous

Gallagher Security and AxxonSoft — Access Control Integration via OPC

Axxon PSIM integrates ACS Gallagher 6000 via OPC to bring access control events into a unified PSIM operator workflow. This enables centralized monitoring, faster incident handling, and consistent security operations across sites.

Quick Overview and Key Benefits of AxxonSoft + Gallagher Security Integration

What Makes the Partnership Valuable

Gallagher provides an access control platform designed for real-time site management and operational workflows (monitoring, reporting, and emergency notifications) through Command Centre.

With Axxon PSIM, Gallagher events can be consolidated into PSIM-driven monitoring and response processes via an OPC-based integration approach. This supports operator-centric workflows where access events are handled consistently alongside other security subsystems connected to Axxon PSIM.

Key Advantages of Axxon PSIM + Gallagher Integration

  • Receives Gallagher pass events in Axxon PSIM → improves operator awareness and speeds up verification workflows.
  • Receives door tampering events → reduces time-to-detect for physical door attacks and abnormal conditions.
  • Receives exit-by-button events → improves clarity of door usage context during incident review and investigations.
  • Uses OPC-based connectivity (via OPC Wrapper) → standardizes third-party connectivity and reduces bespoke integration effort.
  • Supports alarm/event exchange via OPC Alarms & Events (where exposed by the OPC server) → enables consistent alarm-driven handling in the PSIM console.
  • Supports data exchange via OPC Data Access (where exposed by the OPC server) → enables state visualization and operator workflows based on live statuses.
  • Centralizes event handling in a PSIM workflow → improves incident response consistency across shifts and sites.
  • Scales from single-site to multi-site operations → supports growth without changing the operator workflow model.

How It Works — Access Control System Integration

Gallagher 6000 events are exposed through an OPC server and connected into Axxon PSIM using the OPC Wrapper integration module. Axxon PSIM then presents incoming access control events to operators for monitoring, handling, and logging within standardized PSIM workflows.

  • Receives access control events (e.g., passes, door tampering, exit by button).
  • Visualizes event details in the Axxon PSIM interface for operator review and triage.
  • Routes received events with site/security context inside PSIM workflows (e.g., incident handling runbooks).
  • Triggers operator attention and response steps based on event type and severity (typical workflow).
  • Automates rule-driven handling supported by the OPC approach (where configured and supported by the OPC server and PSIM logic).
  • Logs event activity for auditability and investigations.

Supported Capabilities

Access Control Workflows

Card Readers

Gallagher’s Card Reader range provides rapid and secure access control management with contactless card readers.

Controllers

Gallagher Controllers are the interface between the Command Centre server and hardware on a site. The modular design of the controllers ensures a cost-effective approach to creating a Gallagher access solution, while straightforward system architecture provides powerful and flexible configuration options.

HBUS Modules and I/O Devices

Gallagher HBUS Modules offer the added features of speed, reliability, connectivity, and high-level data protection to your site management solution.

Flexible, fast, cost-effective and secure, Gallagher HBUS I/O Devices provide input and output expansion options, extending the connectivity of the Gallagher Controller 6000 and supporting shared cabling with other HBUS devices.

Cabinets

Two Gallagher Cabinets are available to accommodate the Gallagher Controllers and HBUS Module. A range of colors and power supply options are available.

The following events of ACS Gallagher 6000 can be received in the Axxon PSIM software package via OPC protocol:

  • pass events
  • door tampering
  • exit by button

Complete Site Management

Gallagher Command Centre is a powerful software solution designed to help you easily and simply manage access control.

Fully customizable to suit the unique needs of your site, Command Centre allows you to configure, manage, and report on all aspects of your system.

Seamless integration with other products means you work with one powerful software platform, making staff training easier and improving business efficiency.

Whether you require access control across single site facilities or multiple global sites, Command Centre delivers on its promise. You’re in command.

  • Manage cardholders, including their access, cards, and photo identification.
  • Monitor alarms and control all system aspects.
  • Retrieve and report on stored system information.
  • Interface to and exchange information with third-party systems.
  • Configure the site and all system components.

Installation Guide & Documentation

Full technical documentation, compatibility tables, and detailed installation steps are available on the AxxonSoft documentation portal.

Deployment Fit

Intended for deployments running Gallagher 6000 that require centralized access control event handling inside Axxon PSIM using an OPC-based integration model — ranging from a single facility to multi-site security operations.

  • Scalable rollout: start with core event ingestion (passes/door events), expand workflows as needed.
  • Lower integration footprint: leverage OPC standards instead of bespoke point-to-point integration.
  • Operational resilience: centralize monitoring while keeping site systems managed in their native platforms (typical PSIM pattern).
  • Multi-site governance: consistent incident handling across facilities with standardized operator procedures (typical workflow).

Industry Benefits and Use Cases

Data Centers

Data centers require strict access governance and clear incident trails. Axxon PSIM can consolidate door events and video footage into a single operator workflow to reduce time-to-investigate and keep procedures consistent across locations.

Healthcare

Healthcare requires controlled access to sensitive areas while maintaining operational flow. Centralizing access events and door-tampering signals in Axxon PSIM supports duty-of-care workflows and consistent incident documentation for audits.

Commercial Real Estate

Multi-building environments need efficient monitoring without fragmented processes. Consolidating access events into Axxon PSIM supports consistent after-hours handling and phased onboarding by building or tenant scope.

Industrial & Manufacturing

Industrial sites need perimeter/door integrity monitoring and controlled access to restricted zones. Centralized visibility of door-tampering and pass events in Axxon PSIM supports faster triage, consistent escalation, and cleaner investigations.

Need more details on integrations?

Book a personalized demo to review the capabilities, workflows, and performance benefits of integrating Gallagher 6000 events into Axxon PSIM. We’ll map your event list, operator procedures, and deployment architecture to a practical rollout plan aligned with your security operations.

FAQ — Gallagher Security Integration

What exactly is integrated with Axxon PSIM?

ACS Gallagher 6000 is integrated with Axxon PSIM to receive specific access control events via OPC. Confirmed events include passes, door tampering, and exit by button.

See the full integration list

What integration method is used?

The integration is provided via OPC protocol using an OPC Wrapper integration approach. This relies on an OPC server exposing the required data/events.

Open the Guide

Which OPC standards are supported by the OPC Wrapper approach?

The OPC Wrapper integration module supports OPC Data Access (DA 2.0) and OPC Alarms & Events (AE 1.0). Availability of specific points/events depends on what the OPC server exposes.

What do I need to prepare for commissioning?

At minimum:

  • a defined event list and mapping (passes / door tamper / exit by button)
  • OPC server endpoint details and exposed namespaces/points
  • operator workflow requirements (acknowledgment, escalation, reporting) aligned with PSIM procedures

Is this integration limited to a single site?

No — this approach is commonly used to centralize monitoring across sites, depending on your OPC server architecture and PSIM deployment model.